Features

1. Enhanced Reliability

Built-in EMC Filter

Reinforced Material Design

MIL217PLUS based Design

UL 61800-5-1 Design

2. High Performance

Application Adaptability

Enhanced V/F Performance

More Powerful Sensorless Control function

3. User Convenience

Built-in Potentiometer

DIN rail Mountable (below 4kW)

Output 2 Relays

Easy to connect to Peripherals (SMART Copier connection)

Frame Design

Specification

3-Phase 200V Class (0.4~7.5kW)
G100-2 0004 0008 0015 0022 0040 0055 0075
Motor Rating Heavy Duty (HD) (HP) 0.5 1.0 2.0 3.0 5 7.5 10
(kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5
Normal Duty (ND) (HP) 1.0 2.0 3.0 5 7.5 10 15
(kW) 0.75 1.5 2.2 4.0 5.5 7.5 11
Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.5 9.1 12.2
Normal Duty (ND) 1.2 2.3 3.8 4.6 6.9 11.4 15.2
Rated Current
(3-Phase Input) [A]
Heavy Duty (HD) 2.5 5.0 8.5 11.0 17.0 24.0 32.0
Normal Duty (ND) 3.1 6.0 9.6 12.0 18.0 30.0 40.0
Rated Current
(1-Phase Input) [A]
Heavy Duty (HD) 1.5 2.8 4.6 6.1 9.3 12.8 17.4
Normal Duty (ND) 2.0 3.6 5.9 6.7 9.8 16.3 22.0
Frequency [Hz] 0~400Hz (IM sensorless: 0~120Hz)
Voltage [V] 3-Phase 200~240V
Input Rating Voltage [V] 3-Phase 200~240VAC (-15%~+10%)
Frequency [Hz] 50~60Hz (±5%)
Rated Current [A] Heavy Duty (HD) 2.2 4.9 8.4 11.8 18.5 25.8 34.9
Normal Duty (ND) 3.0 6.3 10.8 13.1 19.4 32.7 44.2
Weight [kg] 1.04 1.06 1.36 1.4 1.89 3.08 3.21
3-Phase 400V Class (0.4~7.5kW)
G100-4 0004 0008 0015 0022 0040 0055 0075
Motor Rating Heavy Duty (HD) (HP) 0.5 1.0 2.0 3.0 5 7.5 10
(kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5
Normal Duty (ND) (HP) 1.0 2.0 3.0 5 7.5 10 15
(kW) 0.75 1.5 2.2 4.0 5.5 7.5 11
Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.5 9.1 12.2
Normal Duty (ND) 1.5 2.4 3.9 5.3 7.6 12.2 17.5
Rated Current
(3-Phase Input) [A]
Heavy Duty (HD) 1.3 2.5 4.0 5.5 9.0 12.0 16.0
Normal Duty (ND) 2.0 3.1 5.1 6.9 10.0 16.0 23.0
Rated Current
(1-Phase Input) [A]
Heavy Duty (HD) 0.7 1.4 2.1 2.8 4.9 6.4 8.7
Normal Duty (ND) 1.3 1.9 2.8 3.6 5.4 8.7 12.6
Frequency [Hz] 0~400Hz (IM sensorless: 0~120Hz)
Voltage [V] 3-Phase 380~480V
Input Rating Voltage [V] 3-Phase 380~480VAC (-15%~+10%)
Frequency [Hz] 50~60Hz (±5%)
Rated Current [A] Heavy Duty (HD) 1.1 2.4 4.2 5.9 9.8 12.9 17.5
Normal Duty (ND) 2.0 3.3 5.5 7.5 10.8 17.5 25.4
Weight [kg] 1.02 (1.04) 1.06 (1.08) 1.4 (1.44) 1.42 (1.46) 1.92 (1.98) 3.08 (3.24) 3.12 (3.28)
Control
Control Method V/F, Slip Compensation, Sensorless Vector Frequency Setting
Frequency Setting Resolution Digital command: 0.01Hz
Analog command: 0.06Hz(maximum frequency: 60 Hz)
Frequency Accuracy 1% of the maximum output frequency
V/F Pattern Linear, squared, user V/F
Overload Capacity HD: 150% 1 minute, ND: 120% 1minute
Torque Boost Manual/Automatic torque boost
Operation
Operation Mode Select key pad, terminal strip, or communication operation
Frequency Setting Analog: -10~10[V], 0~10[V], 4~20[mA]
Digital: Keypad
Operation Function PID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse direction rotation,
Commercial transition, Speed search, Power braking, Leakage reduction, Up-down operation, DC braking,
Frequency jump, Slip compensation, Automatic restart, Automatic tuning,
Energy buffering, Flux braking, Fire mode
Input Multi-Function Terminal
(5 Points)
NPN (Sink) / PNP (Source) Selectable
Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation,
Multi-step frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle, low,
DC braking at stop, 2nd motor select, Frequency up/down, 3-wire operation,
Change into normal operation during PID operation Change into main operation during option operation,
Analog command frequency fixing, Acceleration/deceleration stop etc. Selectable
Analog Input V1: -10~10V, I2 4~20mA
Output Multi-function Relay Terminal Fault output and drive operation status output (N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A
Analog Output 0~12Vdc: Frequency, Output current, Output voltage, DC stage voltage etc. selectable
Protective Function
Trip Over current trip, external signal trip, ARM short
current fault trip, over heat trip, input imaging trip,
ground trip, motor over heat trip,
I/O board trip, no motor trip, parameter writing trip,
emergency stop trip, command loss trip,
external memory error, CPU watchdog trip,
motor light load trip
Over voltage trip, temperature sensor trip,
inverter over heat, option trip,
output image trip, inverter overload trip,
fan trip, pre-PID operation
failure external brake trip,
low voltage trip during operation, low voltage trip,
analog input error, motor overload trip,
over torque trip, under torque trip
Alarm Command loss trip warning, overload warning, light load warning, inverter overload warning,
fan operation warning, braking resistance braking rate warning, rotor time constant tuning error,
inverter pre-overheat warning, over torque warning, under torque warning
Momentary Power Loss HD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage,
rated output) HD above 15ms (ND above 8ms): Automatic restart operation enable
Environment
Cooling Type Forced fan cooling structure
Protection Degree IP20/UL Open (Default), UL Enclosed type 1 (Option)
Ambient Temperature Ambient temperature under the condition of no ice or frost.
HD: -10~50℃(14~122°F) / ND: -10~40℃(14~104°F)
[However, recommended to use load below 80% when using at 50°C under light load]
Humidity Relative humidity below 95% RH (no dew formation)
Storage Temperature -20~65℃(-4~149°F)
Location No corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution degree 2 environment)
Altitude, Vibration Below 1,000m (From 1000 to 4000m, the rated input voltage and rated output current
of the drive must be derated by 1% for every 100m.), below 9.8m/sec2 (1G)
Pressure 70~106kPa

Download

TitleCategoriesDateContentLinkhf:doc_categorieshf:doc_tags
[Drive Solution] Low-Voltage DriveOctober 21, 2021

Drive Solution_Catalog_EN_(05)_211014

catalogautomation g100 h100 is7 m100 s100
[AC Drive] G100 Conduit KitsJuly 2, 2021

Dimension_G100+Conduit_D+FRAME

Dimension_G100+Conduit_A+FRAME

Dimension_G100+Conduit_Series

cad-dataautomation g100
[AC Drive] G100 CatalogJune 21, 2021

G100_Catalog_EN_(05)_210511

catalogautomation g100
[AC Drive] DriveView 9March 29, 2021

Drive_DriveView9_Software_Install+File_V1.2.0._201130

Drive_DriveView9_ReleaseNote_EN_V1.2.0_201201

Drive_DriveView9_Manual_EN_200622

softwareautomation g100 m100
[AC Drive] G100 User ManualSeptember 15, 2020

G100(0.4_7.5kW)_Full_User_Manual_EN_V1.2_200911

manualautomation g100
[AC Drive] iS7 and G100 Dual Port EDS fileFebruary 14, 2020

iS7+G100+Dual+Port+EthernetIP

technical-dataautomation g100 is7
[AC Drive] G100 Ethernet Option User ManualDecember 11, 2019

G100+Ethernet+Option_EN_191030

manualautomation g100
[AC Drive] Modbus RTU Register TableNovember 28, 2019

Modbus+RTU+Register+Table+Rev+B

technical-dataautomation g100
[AC Drive] C100 to G100 Transition GuideNovember 20, 2019

C100_G100+Transistion+Guide_Rev+B

manualautomation g100
[AC Drive] G100 Quick Start ReferenceNovember 20, 2019

G100+QSR+Rev+C

manualautomation g100
[Video] G100 Series Promotion VideoJune 13, 2019

LS_G100_ENG_60Hz_Short

catalogautomation g100
[AC Drive] LS Drives Watt Loss DataMay 30, 2019

LSIS+VFD+Watt+Loss+and+Efficiency+Bulletin+Rev+F

technical-dataautomation g100
[AC Drive] 3-Wire ControlDecember 28, 2016

3-Wire+Control+Rev+A

technical-datag100 h100 is7 m100 s100
[AC Drive] LV Drive Series CatalogSeptember 18, 2014

LV+Drive+Series_USA_202007 (1)

manualautomation g100
[AC Drive] LSIS AC Drive Series Brochure – OverviewSeptember 18, 2014

LV+Drive+Series_140813

catalogautomation g100 h100 is7 m100 s100

Location

625 Heathrow Dr.
Lincolnshire, IL. 60069, USA

Sales: (800) 891-2941
sales.us@lselectricamerica.com
Tech Support: (800) 891-2941

      

Copyright © 2021 LS Electric America. All Rights Reserved.

All ProductsAutomationG100