1. Strong Performance
Powerful sensorless control
Starting torque of 200%/0.5Hz is produced and provides robust power in the low speed region.
Selectable rotary/standstill auto-tuning
Standstill auto-tuning is equipped to find motor constants without rotation under conditions where the system is installed or the motor cannot rotate.
Flying start function
Inverter capable of quick, reliable, and smooth restart into bi-directional rotating loads.
2. Space efficient design
Side by side installation
Minimized distance between products enables control panel size reduction when installing multiple AC Drives
Smaller Size
Main parts are optimally arranged inside through the use of thermal radiation analysis and 3-dimensional design to reduce the dimensions by up to 60% (volume based) compared to the previous product (iG5A)
3. Standard Compliance
Built-in DC reactor
Effective in improving power factors and decreasing THD
※ 3-phase 400V 30~75kW
Built-in EMC filter
Meets the electrical noise reduction regulation
Related standards: Certified 2nd Environment/Category C3 (Class A) CE standard
※ C2 : 1-phase 200V 0.4~2.2kW
※ C3 : 3-phase 400V 0.4~75kW
Global compliance (UL, CE)
Global standard compliance
※ UL, CE, Gost, C-tick and cUL
Dual rating operation
Designed to choose between heavy and normal duty operations
Overload capacity
※ Heavy duty operation : 150% of rated current, 60 seconds
※ Normal duty operation : 120% of rated current, 60 seconds
Various field networks
Able to deal with a variety of field networks easy maintenance and mounting.
Various field bus options
Profibus, Ethernet IP, Modbus TCP, CANopen Easy to install and use
4. Safety Function
Built-in Safety Torque Off (STO)
The Safety input function meets EN ISO 13849-1 PLd and EN 61508 SIL2 (En 60204-1, stop category 0)
This feature is equipped and meets current safety standards
5. Suitable for Users
Simple cooling fan replacement
Replaceable fan without complete disassembly
1. Smart copier allows users to download & upload the parameters from/to S100 without AC input power.
2. Customized main firmware is able to be downloaded to S100 using Smart copier.
3. Firmware of main control and I/O saved in Smart copier can be downloaded to S100
Multi-keypad function
A single LCD keypad can be used to set up the parameters of a RS485 connected drive
LCD keypad (same as iS7 model) is used to easily set up parameters. Parameters can be copied to other drives
Multi language support will be available
Conduit option
S100 meets UL type 1 with this option.
Flange option
With this option, S100 allows its heatsink to be installed outside of the panel for a better cooling system.
Frame Design


Specification
1-Phase 200V (0.4~2.2kW)
LSLV S100-1 | 0004 | 0008 | 0015 | 0022 | ||
---|---|---|---|---|---|---|
Motor Rating | Heavy Duty(HD) |
[HP] | 0.5 | 1.0 | 2.0 | 3.0 |
[kW] | 0.4 | 0.75 | 1.5 | 2.2 | ||
Heavy Duty(HD) |
[HP] | 1.0 | 2.0 | 3.0 | 5.0 | |
[kW] | 0.75 | 1.5 | 2.2 | 3.7 | ||
Output Rating | Capacity [kVA] |
Heavy Duty(HD) |
1.0 | 1.9 | 3.0 | 4.2 |
Normal Duty(ND) |
1.2 | 2.3 | 3.8 | 4.6 | ||
Rated Current |
Heavy Duty(HD) |
2.5 | 5.0 | 8.0 | 11.0 | |
Normal Duty(ND) |
3.1 | 6.0 | 9.6 | 12.0 | ||
Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) | |||||
Voltage [V] | 3-phase 200~240V | |||||
Input Rating | Voltage [V] | -phase 200~240VAC (-15% ~ +10%) | ||||
Frequency [Hz] | 50~60Hz ( ±5%) | |||||
Rated Current [A] |
Heavy Duty(HD) |
4.4 | 93. | 15.6 | 21.7 | |
Normal Duty(ND) |
5.8 | 11.7 | 19.7 | 24.0 | ||
Weight [kg] | 0.9 (1.14) |
1.3 (1.76) |
1.5 (1.76) |
2.0 (2.22) |
3-Phase 200V (0.4~15kW)
LSLV S100-2 | 0004 | 0008 | 0015 | 0022 | 0037 | 0040 | 0055 | 0075 | 0110 | 0150 | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor Rating | Heavy Duty(HD) |
[HP] | 0.5 | 1.0 | 2.0 | 3.0 | 5.0 | 5.4 | 7.5 | 10.0 | 15.0 | 20.0 |
[kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11.0 | 15.0 | ||
Heavy Duty(HD) |
[HP] | 1.0 | 2.0 | 3.0 | 5.0 | 5.4 | 7.5 | 10.0 | 15.0 | 20.0 | 25.0 | |
[kW] | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | 11.0 | 15.0 | 18.5 | ||
Output Rating | Capacity [kVA] |
Heavy Duty(HD) |
1.0 | 1.9 | 3.0 | 4.2 | 6.1 | 6.5 | 9.1 | 12.2 | 17.5 | 22.9 |
Normal Duty(ND) |
1.2 | 2.3 | 3.8 | 4.6 | 6.9 | 6.9 | 11.4 | 15.2 | 21.3 | 26.3 | ||
Rated Current [3-Phase input] (A) |
Heavy Duty(HD) |
2.5 | 5.0 | 8.0 | 11.0 | 16.0 | 17.0 | 24.0 | 32.0 | 46.0 | 60.0 | |
Normal Duty(ND) |
3.1 | 6.0 | 9.6 | 12.0 | 18.0 | 18.0 | 30.0 | 40.0 | 56.0 | 69.0 | ||
Rated Current [Single-Phase input] (A) |
Heavy Duty(HD) |
1.5 | 2.8 | 4.6 | 6.1 | 8.8 | 9.3 | 13.0 | 18.0 | 26.0 | 33.0 | |
Normal Duty(ND) |
1.8 | 3.3 | 5.7 | 6.6 | 9.9 | 9.9 | 16.0 | 22.0 | 31.0 | 38.0 | ||
Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) | |||||||||||
Voltage [V] | 3-phase 200~240V | |||||||||||
Input Rating | Voltage [V] | 3-Phase 200~240VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) |
||||||||||
Frequency [Hz] | 50~60Hz (±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) |
|||||||||||
Rated Current [A] |
Heavy Duty(HD) |
2.2 | 4.9 | 8.4 | 11.8 | 17.5 | 18.5 | 25.8 | 34.9 | 50.8 | 66.7 | |
Normal Duty(ND) |
3.0 | 6.3 | 10.8 | 13.1 | 19.4 | 19.4 | 32.7 | 44.2 | 62.3 | 77.2 | ||
Weight [kg] | 0.9 | 0.9 | 1.3 | 1.5 | 2.0 | 2.0 | 3.3 | 3.3 | 4.6 | 7.1 |
3-Phase 400V (30~75kW)
LSLV S100-4 | 0300 | 0370 | 0450 | 0550 | 0750 | ||
---|---|---|---|---|---|---|---|
Motor Rating | Heavy Duty(HD) |
[HP] | 40.0 | 50.0 | 60.0 | 75.0 | 100.0 |
[kW] | 30.0 | 37.0 | 45.0 | 55.0 | 75.0 | ||
Heavy Duty(HD) |
[HP] | 50.0 | 60.0 | 75.0 | 100.0 | 120.0 | |
[kW] | 37.0 | 45.0 | 55.0 | 75.0 | 90.0 | ||
Output Rating | Capacity [kVA] |
Heavy Duty(HD) |
46 | 57 | 69 | 84 | 116 |
Normal Duty(ND) |
55 | 67 | 78 | 106 | 126 | ||
Rated Current [3-Phase input] (A) |
Heavy Duty(HD) |
61.0 | 75.0 | 91.0 | 110 | 152.0 | |
Normal Duty(ND) |
75 | 91 | 107 | 142 | 169.0 | ||
Rated Current [Single-Phase input] (A) |
Heavy Duty(HD) |
32 | 39 | 47 | 57 | 78 | |
Normal Duty(ND) |
39 | 47 | 55 | 73 | 87 | ||
Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) | ||||||
Voltage [V] | 3-phase 380~480V | ||||||
Input Rating | Voltage [V] | 3-Phase 380~480VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) |
|||||
Frequency [Hz] | 50~60Hz ( ±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) |
||||||
Rated Current [A] |
Heavy Duty(HD) |
56.0 | 69.0 | 85.0 | 103.0 | 143.0 | |
Normal Duty(ND) |
69.0 | 85.0 | 100.0 | 134.0 | 160.0 | ||
Weight [kg] | 25.8 | 34.4 | 34.4 | 41.8 | 43.8 |
Download
S100_Catalog_202211.pdf Drive Solution_Catalog_EN_(05)_211014 S100+Profibus_User+Manual_EN_200615 iS7_Technical+Data_Profibus_V2.01_150519 iS7_User+Manual_Profibus+DP_Eng_Kor_V1.3_200610 iS7_User+Manual_PROFInet_Eng_Kor_V1.1_200701 S100_Manual_English_V2.8_200615 iS7_H100_User+Manual_NEMA+KEYPAD+OPTION_V1.00_161013_EN S100+PM+Motor+Rev+A S100+EthernetIP S100+QSR+(40-100HP)+Rev+C S100+QSR+(.5-30HP)+Rev+C S100_Manual_English_V2.8_200615 EtherCAT+ESI S100+Ethernet+Module+Allen+Bradley+PLC+Setup+Guide+Rev+C 3-Wire+Control+Rev+A Flashing+Firmware+Procedure+S100+Rev+A S100+flyer(Revised+170428) S100_H100_iS7+User+Group+and+lock+Parameters+Setup+Guide Dimension+diagram_S100 LV+Drive+Series_140813 GSDML-V2.31-LSIS-S100-20160110Title Categories Date Content Link hf:doc_categories hf:doc_tags S100 Catalog Catalog November 15, 2022 catalog automation s100 [Drive Solution] Low-Voltage Drive Catalog October 21, 2021 catalog automation g100 h100 is7 m100 s100 [AC Drive] S100 Profibus Manual Manual November 17, 2020 manual automation s100 [AC Drive] iS7 Profibus Option Manual and GSD Technical Data October 26, 2020 technical-data panel-control s100 [AC Drive] S100 User Manual Manual September 15, 2020 manual automation s100 vfs [AC Drive] iS7 and H100 NEMA 4X Keypad Kit Manual July 14, 2020 manual automation h100 is7 s100 [AC Drive] S100 PM Motor Setup Technical Data June 8, 2019 technical-data automation s100 [AC Drive] S100 EDS File Technical Data June 8, 2019 technical-data automation s100 [AC Drive] S100 Quick Start Reference Manual May 9, 2019 manual automation s100 [AC Drive] S100 Quick Start Reference Manual May 9, 2019 manual automation s100 [AC Drive] S100 4X Ethernet InstallationS1004X+Ethernet+Install+Rev+A Technical Data August 18, 2018 technical-data automation s100 [AC Drive] S100 – EtherCAT Manual and Files Manual January 16, 2018 manual automation s100 [AC Drive] S100 – EtherCAT Manual and Files Technical Data January 16, 2018 technical-data automation s100 [AC Drive] S100 – Allen Bradley PLC Ethernet IP Setup Rev C Technical Data January 5, 2018 technical-data automation s100 [AC Drive] 3-Wire Control Technical Data December 28, 2016 technical-data g100 h100 is7 m100 s100 [AC Drive] S100 – Flashing Firmware Procedure Technical Data December 15, 2016 technical-data automation s100 [AC Drive] 2page Flyers for VFDs Catalog October 3, 2015 catalog automation h100 is7 s100 [AC Drive] 2page Flyers for VFDs Catalog October 3, 2015
catalog automation h100 is7 s100 [AC Drive] S100_H100_iS7 User Group and lock Parameters Setup Guide Technical Data March 25, 2015 technical-data automation h100 s100 [AC Drive] LSLV S100 Series Dimensional Drawing CAD Data September 23, 2014 cad-data automation s100 [AC Drive] LSIS AC Drive Series Brochure – Overview Catalog September 18, 2014 catalog automation g100 h100 is7 m100 s100 [AC Drive] S100 ProfiNet GSDML Technical Data March 17, 2014 technical-data automation s100
About Us
Location
625 Heathrow Dr.
Lincolnshire, IL. 60069, USA
Sales: (800) 891-2941