Metasol MMS

LS Manual Motor Starters(MMS) is a motor protection product with high performance and reliability. This product has higher technology and expertise than the existing Meta-MEC MMS due to existing overload and phase failure protection functions, upgraded short-circuit capabilities and quality. In addition, all user conditions were met in accordance with IEC and UL standards

Features

Specification

Download

Features

  • Enhanced trip function
    • New application of MMS-32/63 trip indicator enhances the visibility of trip
  • Reinforced product reliability
    • Reinforced breaking reliability compared to existing -MEC MMS
  • Compatibility and design differentiation
    • Same external dimension with -MEC MMS
    • Consistency with sol MC by changing appearance color
  • Various protection features
    • Over load
    • Short circuit
    • Phase failure protection
  • Size
    • MMS-32D follows DIN 43880 standards

Specification

Standard type

Type Rated
operational
current Ie[A]
Themal
release
Adjustment
range[A]
Magnetic
release
Operating
current[A]
Switching of 3 phase AC motors, AC-2, AC-3 400/415V
3-phase[kW](50/60Hz) 3-phase[HP](60Hz)
230V 400V 690V 230V 460V 575V Icu[kA] Icu[kA]
MMS-32D 0.16 0.1~0.16 2.3 0.06 100 100
0.25 0.16~0.25 3.6 0.06 0.12 100 100
0.4 0.25~0.4 5.8 0.06 0.09 0.18 100 100
0.63 0.4~0.63 9.1 0.09 0.18 0.25 100 100
1 0.63~1 14.4 0.18 0.25 0.55 1/2 100 100
1.6 1.~1.6 23.0 0.25 0.55 1.1 3/4 3/4 100 100
2.5 1.6~2.5 36.0 0.37 0.75 1.5 1/2 1 1.5 100 100
4 2.5~4 57.6 0.75 1.5 3.0 3/4 2 3 100 100
6.3 4~6.3 90.7 1.5 2.2 4.0 1.5 3 5 100 100
10 6~10 144.0 2.2 4.0 7.5 3 5 7.5 100 100
14 9~14 201.6 3.0 5.5 11 3 10 10 15 7.5
18 13~18 259.2 4.0 7.5 15 5 10 15 15 7.5
23 17~23 331.2 5.5 11 18.5 7.5 15 20 15 6
25 20~25 360.0 5.5 11 22 7.5 15 20 15 6
32 24~32 460.8 7.5 15 30 10 20 25 10 6
MMS-32S 0.16 0.1…0.16 2.1 0.02 100 100
0.25 0.16…0.25 3.3 0.03 0.06 100 100
0.4 0.25…0.4 5.2 0.06 0.09 100 100
0.63 0.4…0.63 8.2 0.09 0.12 0.25 100 100
1 0.63…1.0 13 0.12 0.25 0.55 1/2 1/2 100 100
1.6 1.0…1.6 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100
2.5 1.6…2.5 32.5 0.37 0.75 1.5 1/2 100 100
4 2.5…4.0 52 0.75 1.5 3 1 2 3 100 100
6 4…6 78 1.5 2.2 4 5 5 100 100
8 5…8 104 1.5 3 5.5 2 5 5 100 100
10 6…10 130 3 4 7.5 3 10 50 38
13 9…13 169 3 5.5 11 3 10 50 38
17 11…17 221 4 7.5 11 5 10 15 20 15
22 14…22 286 4 7.5 15 15 20 15 11
26 18…26 338 5.5 11 18.5 15 20 15 11
32 22…32 416 7.5 15 22 10 20 30 15 11
40 28…40 520 7.5 18.5 30 15 30 40 10 8
MMS-63S 10 6~10 130 3 4 7.5 3 10 100 100
13 9~13 169 3 5.5 11 3 10 50 38
17 11~17 221 4 7.5 11 5 10 15 25 19
22 14~22 286 4 7.5 15 15 20 25 19
26 18~26 338 5.5 11 18.5 10 20 25 25 19
32 22~32 416 7.5 15 22 10 25 30 25 19
40 28~40 520 7.5 18.5 30 15 30 40 25 19
50 34~50 650 11 22 45 15 40 50 25 19
63 45~63 819 15 30 55 20 50 60 25 19
65 47~65 845 15 30 55 20 50 60 25 19
MMS-100S 17 11~17 221 4 7.5 11 5 10 15 50 38
22 14~22 286 4 7.5 15 15 20 50 38
26 18~26 338 5.5 11 18.5 10 20 25 50 38
32 22~32 416 7.5 15 22 10 25 30 50 38
40 28~40 520 7.5 18.5 30 15 30 40 50 38
50 34~50 650 11 22 45 15 40 50 50 38
63 45~63 819 15 30 55 20 50 60 50 38
75 55~75 975 22 37 63 25 60 75 50 38
90 70~90 1170 30 45 75 30 75 100 50 38
100 80~100 1300 30 45 90 40 75 100 50 38

 

High breaking type

Type Rated
operational
current Ie[A]
Themal
release
Adjustment
range[A]
Magnetic
release
Operating
current[A]
Switching of 3 phase AC motors, AC-2, AC-3 400/415V
3-phase[kW](50/60Hz) 3-phase[HP](60Hz)
230V 400V 690V 230V 460V 575V Icu[kA] Icu[kA]
MMS-32H 0.16 0.1…0.16 2.1 0.02 100 100
0.25 0.16…0.25 3.3 0.03 0.06 100 100
0.4 0.25…0.4 5.2 0.06 0.09 100 100
0.63 0.4…0.63 8.2 0.09 0.12 0.25 100 100
1 0.63…1.0 13 0.12 0.25 0.55 1/2 1/2 100 100
1.6 1.0…1.6 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100
2.5 1.6…2.5 32.5 0.37 0.75 1.5 1/2 100 100
4 2.5…4.0 52 0.75 1.5 3 1 2 3 100 100
6 4…6 78 1.5 2.2 4 5 5 100 100
8 5…8 104 1.5 3 5.5 2 5 5 100 100
10 6…10 130 3 4 7.5 3 10 100 100
13 9…13 169 3 5.5 11 3 10 100 100
17 11…17 221 4 7.5 11 5 10 15 50 38
22 14…22 286 4 7.5 15 15 20 50 38
26 18…26 338 5.5 11 18.5 15 20 50 38
32 22…32 416 7.5 15 22 10 20 30 50 38
40 28~40 520 7.5 18.5 30 15 30 40 40 30
MMS-63H 10 6~10 130 3 4 7.5 3 10 100 100
13 9~13 169 3 5.5 11 3 10 100 100
17 11~17 221 4 7.5 11 5 10 15 50 50
22 14~22 286 4 7.5 15 15 20 50 50
26 18~26 338 5.5 11 18.5 10 20 25 50 50
32 22~32 416 7.5 15 22 10 25 30 50 50
40 28~40 520 7.5 18.5 30 15 30 40 50 50
50 34~50 650 11 22 45 15 40 50 50 50
63 45~63 819 15 30 55 20 50 60 50 50
65 47~65 845 15 30 55 20 50 60 35 27
MMS-100 17 11~17 221 4 7.5 11 5 10 15 100 100
22 14~22 286 4 7.5 15 15 20 100 50
26 18~26 338 5.5 11 18.5 10 20 25 100 50
32 22~32 416 7.5 15 22 10 25 30 100 50
40 28~40 520 7.5 18.5 30 15 30 40 100 50
50 34~50 650 11 22 45 15 40 50 100 50
63 45~63 819 15 30 55 20 50 60 100 50
75 55~75 975 22 37 63 25 60 75 75 50
90 70~90 1170 30 45 75 30 75 100 75 50
100 80~100 1300 30 45 90 40 75 100 75 50

Instantaneous type

Type Rated
operational
current Ie[A]
Themal
release
Adjustment
range[A]
Magnetic
release
Operating
current[A]
Switching of 3 phase AC motors, AC-2, AC-3 400/415V
3-phase[kW](50/60Hz) 3-phase[HP](60Hz)
230V 400V 690V 230V 400V 575V Icu[kA] Icu[kA]
MMS-32HI 0.16 2.1 0.02 100 100
0.25 3.3 0.03 0.06 100 100
0.4 5.2 0.06 0.09 100 100
0.63 8.2 0.09 0.12 0.25 100 100
1 13 0.12 0.25 0.55 1/2 1/2 100 100
1.6 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100
2.5 32.5 0.37 0.75 1.5 1/2 100 100
4 52 0.75 1.5 3 1 2 3 100 100
6 78 1.5 2.2 4 5 5 100 100
8 104 1.5 3 5.5 2 5 5 100 100
10 130 3 4 7.5 3 10 100 100
13 169 3 5.5 11 3 10 100 100
17 221 4 7.5 11 5 10 15 50 38
22 286 4 7.5 15 15 20 50 38
26 338 5.5 11 18.5 15 20 50 38
32 416 7.5 15 22 10 20 30 50 38
40 520 7.5 18.5 30 15 30 40 40 30
MMS-63HI 10 130 3 4 7.5 3 10 100 100
13 169 3 5.5 11 3 10 100 100
17 221 4 7.5 11 5 10 15 50 50
22 286 4 7.5 15 15 20 50 50
26 338 5.5 11 18.5 10 20 25 50 50
32 416 7.5 15 22 10 25 30 50 50
40 520 7.5 18.5 30 15 30 40 50 50
50 650 11 22 45 15 40 50 50 50
63 819 15 30 55 20 50 60 50 50
65 845 15 30 55 20 50 60 35 27
MMS-100HI 17 221 4 7.5 11 5 10 15 100 100
22 286 4 7.5 15 15 20 100 50
26 338 5.5 11 18.5 10 20 25 100 50
32 416 7.5 15 22 10 25 30 100 50
40 520 7.5 18.5 30 15 30 40 100 50
50 650 11 22 45 15 40 50 100 50
63 819 15 30 55 20 50 60 100 50
75 975 22 37 63 25 60 75 75 50
90 1170 30 45 75 30 75 100 75 50
100 1300 30 45 90 40 75 100 75 50

Downloads

8 documents
MMS_UL_#1
April 19, 2020

MMS-32, MMS-63, MMS-100

save Icon
MMS_UL_#2
April 19, 2020

INDUSTRIAL CONTROL PANELS. General Coverage

save Icon
MMS_UL_#3
April 19, 2020

USL, CNL – Enclosures for Industrial Control Panels. EPH32 series, Models EPH32 followed by Blank or X, followed by -65, followed by S or F.

save Icon
MMS_UL_#4
April 17, 2020

MMS Series. Models MMS-32 followed by H or HI or S, maybe followed by -0.16, -0.25, -0.40, -0.63, -1.0, -1.6, -2.5, -4.0, -6.0, -8.0, -10, -13, -17, -22, -26, –32 or -40. Models MMS-63 followed by H or HI or S, maybe followed by -10, -13, -17, -22, -26, -32, -40, -50, –63 or -65. Models MMS-100 followed by H or HI or S, maybe followed by -17, -22, -26, -32, -40, -50, -63, -75, -90 or -100, MMS Front Mounted Auxiliary Contact Block Accessory Model FX, MMS Side Mounted Auxiliary Contact Block Accessory Model LX, MMS Shunt Release Accessory RS Series, MMS Undervoltage Release Accessory RU Series, MMS Undervoltage Release with Switch Accessory RUX Series, MMS Alarm Switch Accessory Model LA, MMS Alarm Switch for Magnetic Trip Accessory Model LAM, MMS Phase-Bus Devices, Type PB-322, PBL-322, PB-323, PBL-323, PB-324, PB-325, PB-632 and PB-633, Direct Adaptor devices, Type DA, followed by –16, –32, 63 or 95, MEH Handles for MMS Series, Models MEH followed by -32, -63 or -100, maybe followed by R, followed by -115 or -315, MMS Line Terminal Block, Type LTB-32, MMS Terminal Block, Type TB-32

save Icon
[MMS] Manual Motor Starters 2D CAD
November 18, 2019
save Icon
[MMS] Enclosure Type MMS
save Icon
8 documents

Location

625 Heathrow Dr.
Lincolnshire, IL. 60069, USA

Sales: (800) 891-2941
sales.us@lselectricamerica.com
Tech Support: (800) 891-2941

      

Copyright © 2021 LS Electric America. All Rights Reserved.

All ProductsPanel ControlsMetasol MMS