Download Center

You can download manuals and various files related to LS ELECTRIC products.

Automation

Panel Control

^

EMPR

^

MCB

^

MMS

^

MS

^

ACB

^

MCCB

Power Distribution

Renewable Energy

  • All
    • Drawings
    • Catalogs
    • Certificates
    • Manuals
    • Software
    • Tech Data
159 documents
[Susol MCCB] TS1600 OCR
November 8, 2023

File 1. [Susol MCCB] TS1600 Manual

save Icon
[Device] Electric Product
September 23, 2023
save Icon
[IMP Series]_Catalog_EN_202003
September 21, 2023
save Icon
[Susol UL MCCB] UL891 SWGR Solution
save Icon
[Susol MCCB] Address map for ETM trip unit
save Icon
[GMP Series]_Catalog_EN_202003
save Icon
[MMP Series]_Catalog_EN_202003
save Icon
Metasol MS_UL_#12
December 31, 2022

MC-100a, MC-130, MC-130a, MC-150, MC-150a

save Icon
[Susol UL MCCB] Up to 1000Vac
December 22, 2022
save Icon
[DPR1000] User Manual (June. 2020)
December 20, 2022
save Icon
Metasol MS_UL_#9
September 7, 2022

MT Series MT, followed by –32, –63, –95 or -150, followed by /2H, /3H, /3K, /F2, /F3, /FK /3D, /FD, UZ Series UZ, followed by –32, -63, -95 and –150

save Icon
Susol UL MCCB_UL_#29
August 2, 2022

AL400TS

save Icon
Susol UL MCCB_UL_#2
July 5, 2022

UTV250, followed by B,F,S,R,E,N or H, may be followed by T, may be followed by MCS , Molded Case Switch

save Icon
Metasol MS_UL_#10
May 17, 2022

MW-9, GMW-12, GMW-18, GMW-22, GMW-32, GMW-40, GMW-50, GMW-65, GMW-75, GMW-85

save Icon
[DPR1000] User Manual EN
save Icon
Metasol MS_UL_#11
March 15, 2022

Industrial Control Equipment, Magnetic Motor Controllers, Models GMC, followed by -100, -125, -150, -180, -220, Industrial Control Equipment, Magnetic Motor Controllers, Models GMC, followed by -100, -125, -150, -180, -220, -300, -400, -600, and –800, may be followed by /R, may be followed by /4, and models MC, followed by -185a, -225a, -265a, -330a, -400a, -500a, -600a, -630a and -800a, may be followed by /R, may be followed by /4, and models MC, followed by -100a/4, -130a/4, 150a/4 , -185a/4, -225a/4, -330a/4, -400a/4, -500a/4, -630a/4 and -800a/4. Accessory latch units AL-100, -150, -200, -400, interlock units AR-100, -180, -600, -600 V

save Icon
Susol UL MCCB_UL_#4
December 14, 2021

Circuit Breakers with Equipment Ground-fault Protection, Type UA, followed by N or S, followed by -08 or -12, followed by C or V, followed by 3 or 4

save Icon
Susol UL MCCB_UL_#5
November 29, 2021

Molded Case Circuit Breakers, Type UA, followed by N or S, followed by -08 or -12, followed by C or V, followed by 3 or 4.

save Icon
Susol UL MCCB_UL_#53
November 13, 2021

Molded Case Switches, Type UA, followed by A, followed by -08 or -12, followed by C or V, followed by 3 or 4

save Icon
Susol UL MCCB_UL_#6
May 13, 2021

Enclosed BPS Molded-Case Switch, Types UBCP-15-08, UBCP-15-16, UBCP-15-20, and UBCP-15-25

save Icon
Susol UL MCCB_UL_#7
May 13, 2021

Molded Case Circuit Breakers – Types UTS600N, UTS600H and UTS600L, rated 500 through 600 A, 600 V ac and 600 V dc, two and three poles.

save Icon
[Metasol MCCB] Adjustable
save Icon
[MCCB,ACB] SKM Library Susol MCCB, ACB UL_Software_SW_EN_202002
February 25, 2021
save Icon
Susol UL MCCB_UL_#8
January 21, 2021

Molded Case Circuit Breakers – Types TS 800NU, TS 800HU rated 500 through 800 A, 600 V ac and 250 V/ 600 V dc, two and three poles

save Icon
Susol UL MCCB_UL_#10
January 21, 2021

Molded Case Circuit Breakers – Types UTS150N, UTS150H and UTS150L, rated 40 through 150 A, 600 V ac and 600 V dc, two and three poles.

save Icon
Susol UL MCCB_UL_#11
January 21, 2021

Molded Case Circuit Breakers – Types UTS250N, UTS250H and UTS250L, rated 150 through 250 A, 600 V ac and 600 V dc, two and three poles

save Icon
Susol UL MCCB_UL_#12
January 21, 2021

Molded Case Circuit Breakers – Types UTS400N, UTS400H and UTS400L, rated 250 through 400 A, 600 V ac and 600 V dc, two and three poles

save Icon
MCB_UL_#1
January 13, 2021

USL – Molded Case Circuit Breakers, Cat. No. BK63HU series…

save Icon
Susol UL MCCB_UL_#9
January 12, 2021

USL, CNL Molded Case Circuit Breakers – Type UTE100H, rated 15 through 30A, 600Y/347 V ac, two and three poles and Types UTE100E and UTE100N, rated 15 through 100 A, 600Y/347 V ac and 500 V dc, two and three poles

save Icon
[DMPi] User Manual EN
save Icon
[IMP] User Manual EN
save Icon
[MCCB] Susol UL 891 Switchboard Solution 3D CAD files
save Icon
UL_MCB(BK63H,BK63HU)
September 11, 2020
save Icon
Line card for US Customers
save Icon
Susol UL MCCB_UL_#13
April 21, 2020

Open type, Industrial Control Switches. Open Type MD, followed by 30a, 60a or 100a.

save Icon
Susol UL MCCB_UL_#14
April 20, 2020

Component – Instantaneous trip circuit breaker, Types UTS600, rated 500 A, 600 Vac, three poles, with suffix MCP

save Icon
Susol UL MCCB_UL_#15
April 20, 2020

Instantaneous trip circuit breaker, Types UTS800, rated 800A, 600Vac, three poles, with suffix MCP

save Icon
Susol UL MCCB_UL_#16
April 20, 2020

Instantaneous trip circuit breaker, Types UTS1200, rated 1200 A, 600Vac, three poles, with suffix MCP.

save Icon
Susol UL MCCB_UL_#17
April 20, 2020

Instantaneous trip circuit breaker, Types TS 250NU, TS 250HU rated 1.6 through 220 A, 600 V ac, three poles, with suffix MTU

save Icon
Susol UL MCCB_UL_#18
April 20, 2020

Instantaneous trip circuit breaker, Types UTS150, rated 1.6 through 150 A, 600Y/347V ac or 600 V, three poles, with suffix MCP

save Icon
Susol UL MCCB_UL_#19
April 20, 2020

Instantaneous trip circuit breaker, Types UTS250, rated 160 through 220 A, 600Vac, three poles, with suffix MCP

save Icon
Susol UL MCCB_UL_#20
April 20, 2020

Instantaneous trip circuit breaker, Types UTS400, rated 320 A, 600Vac, three poles, with suffix MCP

save Icon
Susol UL MCCB_UL_#21
April 20, 2020

Circuit Breakers with Equipment Ground-fault Protection Types UTS800N, UTS800H and UTS800L, rated 400 through 800 A, 600 V ac, three poles, Types UTS1200N, UTS1200P, UTS1200H and UTS1200L, rated 800 through 1200 A, 600 V ac, three poles, Types UTS400N, UTS400H and UTS400L, rated 250, 400 A, 600 V ac, three poles, Types UTS600N, UTS600H and UTS600L, rated 400, 600 A, 600 V ac, three poles.

save Icon
Metasol MS_UL_#14
April 19, 2020

Combination Motor Controllers, Type C Combination Motor Controllers consisting of LSIS Inverse-Time Circuit Breakers, MC series Contactors and MT series Overload Relays, Combination Motor Controllers, Type A Combination Motor Controllers consisting of SOCOMEC or ABB OY LOW VOLTAGE SWITCHES Manual Disconnect Device, Branch Circuit Protection Fuse, LSIS MC series Contactors and LSIS MT series Overload Relays

save Icon
MMS_UL_#1
April 19, 2020

MMS-32, MMS-63, MMS-100

save Icon
MMS_UL_#2
April 19, 2020

INDUSTRIAL CONTROL PANELS. General Coverage

save Icon
MMS_UL_#3
April 19, 2020

USL, CNL – Enclosures for Industrial Control Panels. EPH32 series, Models EPH32 followed by Blank or X, followed by -65, followed by S or F.

save Icon
Susol UL MCCB_UL_#22
April 19, 2020

COMBINATION MOTOR CONTROLLERS USL, CNL – Combination Motor Controllers, Type C Combination Motor Controllers consisting of LSIS Inverse-Time Circuit Breakers, MC series Contactors and MT series Overload Relays.

save Icon
MCB_UL_#2
April 19, 2020

Series BK63H. Accessory, AX, AL, UVT, SHT

save Icon
Mini MS_UL_#2
April 18, 2020

SMD-10P, SMD-15P, SMD-20P, SMD-25P, SMD-35P, SMD-48P, SMD-50P, SMD-65P, SMD-80P

save Icon
Susol MS_UL_#4
April 18, 2020

MU-45, MU-55, MU-70

save Icon
Metasol MS_UL_#15
April 18, 2020

GMD-50a, GMD-65a, GMD-75a, GMD-85a,

save Icon
Metasol MS_UL_#16
April 18, 2020

CH-10N/SP

save Icon
Metasol MS_UL_#17
April 18, 2020

MC-6a, MC-9a, MC-12a and MC-18a, may be followed by /4, /R or Blank, SMC-6a, SMC-9a, SMC-12a and SMC-18a, may be followed by /4, /R or Blank, Accessory, Wire Kit – UW-18

save Icon
Metasol MS_UL_#18
April 18, 2020

SMC-10P, SMC-15P, SMC-20P, SMC-25P, SMC-35P, SMC-48P, SMC-50P, SMC-65P, SMC-80P

save Icon
Metasol MS_UL_#19
April 18, 2020

GMC-10P2, GMC-20P2, GMC-25P2, GMC-30P2, GMC-35P2, GMC-40P2

save Icon
Metasol MS_UL_#20
April 18, 2020

Series GMR, followed by -4, -6, or -8, may be followed by D or (D), Accessories – Auxiliary Contact Block, AU-1, AU-2, AU-4 and AU-100

save Icon
Metasol MS_UL_#21
April 18, 2020

US-1, US-2, US-3, US-4, US-5, US-6, US-11, US-12, US-13, US-14, US-22

save Icon
Metasol MS_UL_#22
April 18, 2020

UR-2

save Icon
Metasol MS_UL_#23
April 18, 2020

Model UT series, followed by -1 or -2, followed by N or F

save Icon
Mini MS_UL_#1
April 18, 2020

GMS-6MR, -9MR, and –12MR, may be followed by /3, /K, D/3, or D/K, GMC-, GMD or GMC(D) may be followed by –6M, -9M, -12M, may be followed by F, P or C, GMC or GMD or GMC(D) may be followed by -6MR, -9MR, and –12MR, AT-12M, AS-12M, AR-12M

save Icon
Susol UL MCCB_UL_#23
April 18, 2020

Accessory Devices on Molded Case Switches_USL, Accessory Devices on Adaptor_U니

save Icon
April 18, 2020

alarm switch type AL-HU, auxiliary switch type AX-HU, shunt trip device type SHT-HU, and undervoltage trip device type UVT-HU intended for installation in Type BK63HU circuit breakers

save Icon
Low Voltage_UL_#1
April 17, 2020

GTK, followed by -22L, -40L, or -85L

save Icon
Low Voltage_UL_#2
April 17, 2020

GTK, followed by -22, -40, or -85

save Icon
Low Voltage_UL_#3
April 17, 2020

GT followed by H or K, followed by -100, -150, -220, -400 or -600, may be followed by /3, may be followed by /L, MT followed by -225, -400, -800, may be followed by /2H, /3H, 3K or /3D

save Icon
Low Voltage_UL_#4
April 17, 2020

LSV-I15-NFB-01~12

save Icon
Mini MS_UL_#3
April 17, 2020

GMR-4M, GMR-6M, GMR-8M, GMR-4MD, GMR-6MD, GMR-8MD, AU-1M, AU-2M, AU-4M

save Icon
Susol MS_UL_#5
April 17, 2020

Listed pressure terminal connectors Cat. Nos. AJ-125, AJ-150, AJ-220, AJ-400 and AJ-800.

save Icon
MMS_UL_#4
April 17, 2020

MMS Series. Models MMS-32 followed by H or HI or S, maybe followed by -0.16, -0.25, -0.40, -0.63, -1.0, -1.6, -2.5, -4.0, -6.0, -8.0, -10, -13, -17, -22, -26, –32 or -40. Models MMS-63 followed by H or HI or S, maybe followed by -10, -13, -17, -22, -26, -32, -40, -50, –63 or -65. Models MMS-100 followed by H or HI or S, maybe followed by -17, -22, -26, -32, -40, -50, -63, -75, -90 or -100, MMS Front Mounted Auxiliary Contact Block Accessory Model FX, MMS Side Mounted Auxiliary Contact Block Accessory Model LX, MMS Shunt Release Accessory RS Series, MMS Undervoltage Release Accessory RU Series, MMS Undervoltage Release with Switch Accessory RUX Series, MMS Alarm Switch Accessory Model LA, MMS Alarm Switch for Magnetic Trip Accessory Model LAM, MMS Phase-Bus Devices, Type PB-322, PBL-322, PB-323, PBL-323, PB-324, PB-325, PB-632 and PB-633, Direct Adaptor devices, Type DA, followed by –16, –32, 63 or 95, MEH Handles for MMS Series, Models MEH followed by -32, -63 or -100, maybe followed by R, followed by -115 or -315, MMS Line Terminal Block, Type LTB-32, MMS Terminal Block, Type TB-32

save Icon
Susol UL MCCB_UL_#26
April 17, 2020

LGCA1, LSCA1, LGCA2, LSCA2, LGCA4, LGCA6, LSCA6 and LSCA8. LSCA8US.

save Icon
Susol UL MCCB_UL_#27
April 17, 2020

AL150TS

save Icon
Susol UL MCCB_UL_#28
April 17, 2020

AL600TS

save Icon
Susol UL MCCB_UL_#3
April 17, 2020

Battery Power Supply Molded-case Switches, Series UD, followed by A, followed by “-”, followed by 08, 10, 13, 16, 20 or 25, followed by D, followed by 3 or 4.

save Icon
Susol UL MCCB_UL_#30
April 17, 2020

AL1200TS

save Icon
Susol UL MCCB_UL_#31
April 17, 2020

AL800TS

save Icon
Susol UL MCCB_UL_#32
April 17, 2020

AL250TS

save Icon
Susol UL MCCB_UL_#33
April 17, 2020

Molded Case Switches, Types UTE100E MCS, UTE100N MCS, UTS150N MCS, UTS150H MCS, UTS150L MCS, UTS250N MCS, UTS250H MCS, UTS250L MCS, UTS400N MCS, UTS400H MCS, UTS400L MCS, UTS600N MCS, UTS600H MCS, UTS600L MCS, UTS800N MCS, UTS800H MCS and UTS800L MCS, UTS1200N MCS, UTS1200P MCS, UTS1200H MCS and UTS1200L MCS

save Icon
Susol UL MCCB_UL_#34
April 17, 2020

Molded Case Circuit Breakers – Types UTS800N, UTS800H and UTS800L, rated 400 through 800 A, 600 V ac, three poles.

save Icon
Susol UL MCCB_UL_#35
April 17, 2020

Molded Case Circuit Breakers – Types UTS1200N, UTS1200P, UTS1200H and UTS1200L, rated 800 through 1200 A, 600 V ac, three poles.

save Icon
Susol UL MCCB_UL_#36
April 17, 2020

Molded Case Switches, Types TD 125NA, TS 250NA, TS 400NA, TS 800NA, rated 125-800 A, 240, 480 or 600 V ac, three pole.

save Icon
Susol UL MCCB_UL_#37
April 17, 2020

AL100TE

save Icon
Susol UL MCCB_UL_#13_050620
April 17, 2020

USL, CNL BPS Molded-Case Circuit Breakers – Types UTD400E, UTD400N, UTD400H, UTD600E, UTD600N and UTD600H

save Icon
Susol UL MCCB_UL_#24
April 17, 2020

AL100TE-L

save Icon
Susol UL MCCB_UL_#25
April 17, 2020

types GBN, GBH or GBL; followed by 103; followed by 16, 20, 25, 32, 40, 50, 63, 80 or 100; may be followed by AL or AX, types GBN, GBH or GBL; followed by 203; followed by 125, 160, 200 or 250; may be followed by AL or AX

save Icon
DMPi_UL_#2
April 17, 2020

models DMP followed by –06i or 65i, followed by -S or –T, maybe followed by Z or B, maybe followed by I, maybe followed by M or A

save Icon
GMP_UL
April 17, 2020

GMP22, GMP40, GMP60T, GMP80

save Icon
IMP_UL
April 17, 2020

models IMP followed by -C, followed by –NO, A420 or M485, followed by 10A or 100A

save Icon
MMP_UL
April 17, 2020

MMP-CB,CM,PB,PM,SB or SM ,followed by 10A or 100A (S EMPR)

save Icon
Susol UL MCCB_UL_#38
April 16, 2020

COMPONENT – PANELBOARD AND SWITCHBOARD

save Icon
Susol UL MCCB_UL_#39
April 16, 2020

Component – Panelboards, Type PBI 1200A and PBI

save Icon
Susol UL MCCB_UL_#40
April 16, 2020

COMPONENT – SWITCHBOARDS, DEAD-FRONT : USR, Recognized Component Switchboard Interior, Type INT-6000A, INT-4000A, and INT-2400A; followed by 36X, 45X, 46X, or 66X; followed by UL; may be followed by additional alpha numeric designations for commercial reasons

save Icon
MCB_UL_#3
April 15, 2020

LCP3[+], LCP(a)

save Icon
Susol UL MCCB_UL_#41
April 10, 2020

USL, CNL BPS Molded-Case Circuit Breakers – Types UTD250E, UTD250N, UTD250H

save Icon
Susol UL MCCB_UL_#42
April 10, 2020

USL/CNL – Circuit breaker or molded case switch accessory, Motor Operator(MOP), type MOP-2U and MOP-3U intended for installation in Type UTS 150, TS 250NU, TS 250HU, TS 250NA, UTS 250, TS 400NU, TS 400HU, TS 400NA, UTS 400, UTS 600 circuit breakers or molded case switches

save Icon
Susol UL MCCB_UL_#43
April 10, 2020

Circuit breaker or molded case switch accessory, alarm switch, auxiliary switch, shunt trip, and undervoltage trip intended for installation in Type UTE 100, TD 125NU, TD 125HU, TD 125NA, UTS 150, TS 250NU, TS 250HU, TS 250NA, UTS 250, TS 400NU, TS 400HU, TS 400NA, UTS 400, UTS 600, TS 800NU, TS 800HU, TS 800NA, UTS 800, UTS 1200

save Icon
Susol UL MCCB_UL_#44
April 10, 2020

UTE 100, TD 125NU, TD 125HU, TD 125NA, UTS 150, TS 250NU, TS 250HU, TS 250NA, UTS 250, TS 400NU, TS 400HU, TS 400NA, UTS 400, UTS 600, TS 800NU, TS 800HU, TS 800NA, UTS 800, UTS 1200

save Icon
Susol UL MCCB_UL_#45
April 10, 2020

Lock-off devices intended for installation in Type UTE 100, TD 125NU, TD 125HU, TD 125NA, UTS 150, TS 250NU, TS 250HU, TS 250NA, UTS 250, TS 400NU, TS 400HU, TS 400NA, UTS 400, UTS 600, TS 800NU, TS 800HU, TS 800NA, UTS 800, UTS 1200

save Icon
Susol UL MCCB_UL_#46
April 10, 2020

Rotary Handle intended for installation in Type UTE 100, TD 125NU, TD 125HU, TD 125NA, UTS 150, TS 250NU, TS 250HU, TS 250NA, UTS 250, TS 400NU, TS 400HU, TS 400NA, UTS 400, UTS 600, UTS 800, UTS 1200

save Icon
Susol UL MCCB_UL_#47
April 8, 2020

USL, CNL – PHOTOVOLTAIC (PV) MOLDED-CASE CIRCUIT BREAKER – Types UTD400E, UTD400N, UTD400H, UTD600E, UTD600N and UTD600H

save Icon
Susol UL MCCB_UL_#48
April 8, 2020

PHOTOVOLTAIC (PV) Molded Case Switches – Types UTD400E, UTD400N, UTD400H, UTD600E, UTD600N and UTD600H

save Icon
Susol UL MCCB_UL_#49
April 8, 2020

PHOTOVOLTAIC (PV) Molded-Case Switches – Types UTD250E, UTD250N, UTD250H

save Icon
Susol UL MCCB_UL_#50
April 8, 2020

PHOTOVOLTAIC (PV) MOLDED-CASE CIRCUIT BREAKER – Types UTD250E, UTD250N, UTD250H

save Icon
Susol UL MCCB_UL_#51
April 7, 2020

SWITCHES, MOLDED CASE, FOR USE WITH BATTERY POWER SUPPLIES BPS Molded-case Switches, Types UTD250E, UTD250N, UTD250H

save Icon
DMPi_UL_#1
April 7, 2020

DMP-06, DMP-60

save Icon
DMPi_UL_#3
April 7, 2020

TERMINAL BLOCK DMPi

save Icon
[EMPR] Catalog_EN
save Icon
Susol UL MCCB_UL_#52
March 25, 2020

SWITCHES, MOLDED CASE, FOR USE WITH BATTERY BPS Molded-case Switches, Types UTD400E, UTD400N, UTD400H, UTD600E, UTD600N and UTD600H

save Icon
[Low Voltage] SKM lib_Susol MCCB,ACB_UL
save Icon
[MC] Contactor Screws and Lugs Explained
save Icon
[Metasol MCCB] ABS1203E_SHT assembly
December 12, 2019
save Icon
[Susol MCCB] Electronic type
December 12, 2019
save Icon
[Susol MCCB] Electronic type ETS,ETM
December 12, 2019
save Icon
[Susol MCCB] TS100,TS160,TS250
December 12, 2019
save Icon
[Susol MCCB] TS400,TS630
December 12, 2019
save Icon
[MMS] Manual Motor Starters 2D CAD
November 18, 2019
save Icon
[Susol MCCB] Accessory
October 1, 2019

File 1. [Susol MCCB] AX,AL manual

save Icon
[Susol MCCB] Accessory
October 1, 2019

File 2. [Susol MCCB] SHT,UVT manual

save Icon
[Susol MCCB] Accessory
October 1, 2019

File 3. [Susol MCCB] Terminal cover manual

save Icon
[MCB]3D CAD Files for UL489 and UL1077 MCBs
save Icon
[MCB] 2D CAD Drawings
save Icon
[MCCB] 2D CAD Data for Susol UL MCCB (UTE, UTS)
save Icon
[MC] Coil Change Process for MC/MR Contactor
December 12, 2016
save Icon
[MC] Metasol MC CAD file (Capacitor contactor)
save Icon
[MC] WYE-Delta Starter Selector
save Icon
[MS]Metasol Series Technical Manual (eng.)
save Icon
Coil characteristic data for GMC Contactor
save Icon
Coil characteristic data for GMC-9 ~ GMC-85
save Icon
Definition of Utilization Category
save Icon
Derating of Ith according to temperature (GMC contactor)
save Icon
[MMS] Enclosure Type MMS
save Icon
[MCB] How to separate the Din Rail Clip from MCBs
save Icon
[MS] Meta-MEC Series Contactors & TOR CAD DATA (2)
save Icon
Magnetic contactor Selection table for auto-transformer starter
save Icon
Characteristics of GMC coil
save Icon
Amended Electrical lifetime curve for GMC
save Icon
159 documents

Location

625 Heathrow Dr.
Lincolnshire, IL. 60069, USA

Sales: (800) 891-2941
sales.us@lselectricamerica.com
Tech Support: (800) 891-2941

      

Copyright © 2021 LS Electric America. All Rights Reserved.

Panel Control